(This functionality is available with the Input / Output module) Note that it may be necessary to have a battery installed in the GIF 12. Ensure that no other application is running that could use the parallel port (e.g. Print Manager).

The two GRM10 rec modules display 'low battery' (20 years after purchase) Remarks The device comes with an user manual, short instructions, 2 GRM10 rec modules (64k capacity), power cable, 2 RS232 interface cables, one 5.25 inch floppy disk with (MS DOS) software Dates Catalogued in 2011 by JMR. Photo by JMR.

REC MODUL ZA LEICA WILD T1600 REC MODULE FOR LEICA WILD T1600 na prodaju / for sale email: geometarsv@gmail.com mob: +381 69 780 650. WILD/LIECA REC MODULE DOWNLOAD. The Wild GIF 10 Data Reader is a data transfer unit that permits to transfer data from a Wild GRM10 'rec. Wild REC Module & GIF12 (This functionality is available with the Input / Output module). The files available in the GRM10 (REC Module).

(This functionality is available with the Input / Output module) Note that it may be necessary to have a battery installed in the GIF 12. Ensure that no other application is running that could use the parallel port (e.g. Print Manager).

Maker Wild, Heerbrugg, Switzerland Model GIF 10 Serial Number n/a Dimensions 180 x 130 x 40 mm Image Description The Wild GIF 10 Data Reader is a data transfer unit that permits to transfer data from a Wild GRM10 'rec module' to a computer over a serial; (RS232) interface. The unit is powered from mains supply (110-220 V ac) or an internal 9V battery. Several communication protocols can be set through the key pad on top of the unit. There is a display and a 25 female (Canon) socket on the unit.

Transferring data from the GIF12 Ensure that you have carried out the appropriate steps in the procedure for up to the step for initiating the transfer of the data. You should then have a dialog box on the screen prompting you to 'Select the file to be downloaded' The files available in the GRM10 (REC Module) are displayed in the combo box below the above message. Select the required file and press the OK button to initiate the transfer. Transferring co-ordinate data to the GIF12 Use the command to put the system in a ready state to send co-ordinates to the GIF12. A dialog box should be displayed asking if the data recorder is ready to receive data. If the GIF12 is connected to the appropriate parallel port of the computer and the GRM10 is in the GIF 12, press the OK button.

If the GIF12 is connected to the appropriate parallel port of the computer and the GRM10 is in the GIF 12, press the OK button. A further dialog box is displayed asking you to 'Select the file to upload to on the GIF12'. The files available in the GRM10 (REC Module) are displayed in the combo box below the above message. Select the required file and press the OK button to initiate the transfer. Note that if the 'Overwrite existing data' check box is crossed, the data in the file selected will be overwritten by the transferred data.

The two GRM10 rec modules display 'low battery' (20 years after purchase) Remarks The device comes with an user manual, short instructions, 2 GRM10 rec modules (64k capacity), power cable, 2 RS232 interface cables, one 5.25 inch floppy disk with (MS DOS) software Dates Catalogued in 2011 by JMR. Photo by JMR.

Offering: 2x Wild GIF10 REC module card reader with data cable to the computer and power cable 2x GRM10 64K REC Module fully working condition with min. 8y guarantee NA2002 digital level software v 3.3, 2x new high 1,6 Ah capacity batteries, charger, case LNA2L laser level, new 3,8Ah battery, wall charger, car charder, LPD20 reciver Wild GEB77 original batterys 5 pin connector with new higher capacity cells Anybody having problem with GRM10 Rec module 64K & 16K especially with Error 75,76,79 are welcome to get help. All service and repair to T2000/2002/3000 are also offered.

Wild Grm10 Rec Module Price

(This functionality is available with the Input / Output module) Note that it may be necessary to have a battery installed in the GIF 12. Ensure that no other application is running that could use the parallel port (e.g. Print Manager).

The internal battery provides about 12 hours of operation. Set includes two GRM10 rec(ording) modules. The (MS-DOS) software (Version 2.0, 32k, supplied on 5.25 inch floppy disk) allows for files to be received, sent, displayed, erased, created and copied. History & comments circa 1990. Conservation No case. Condition in mint condition.

$95   $ 75   LEICA GEB211 GEB-211   LEICA GEB221 GEB-221 2.0 Ah Li-Ion 4.0 Ah Li-Ion WE DO REPAIR   $69   $ 99   LEICA GRM10   Rec Module.See Note Below Data Battery Software Battery Reprogramming WE DO REPAIR   $35   $35   $50   LEICA 399 RTK GPS RANGE POLE   BATTERY 3.7 Ah NiMH WE DO REPAIR   $199 For Use With Leica Total Staions Allows you to run your total station on a work bench or in the office from a wall outlet   $85 #1 Most GEB111 and GEB121 battery packs that are replaced with off-the-shelf camcorder batteries will not work properly with the LEICA battery charger. The temperature protection devices inside the after-market packs may not be compatible with the LEICA charger and cause the battery not to charge properly and severely shorten its life-span. It is always best to rebuild the original LEICA packs using the original temperature devices. #2 Most rec modules have now reached the age where both data and software batteries need to be replaced. When the software battery goes dead, all programming is lost and module will no longer communicate with the equipment.even if the data battery is replaced.

If there is not enough room in the selected file, an error message is displayed and no data is transferred.

Transferring data from the GIF12 Ensure that you have carried out the appropriate steps in the procedure for up to the step for initiating the transfer of the data. You should then have a dialog box on the screen prompting you to 'Select the file to be downloaded' The files available in the GRM10 (REC Module) are displayed in the combo box below the above message. Select the required file and press the OK button to initiate the transfer. Transferring co-ordinate data to the GIF12 Use the command to put the system in a ready state to send co-ordinates to the GIF12. A dialog box should be displayed asking if the data recorder is ready to receive data.

All service and repair to T2000/2002/3000 are also offered.

The Input and output operations transfer the data from or to the PCMCIA card in that drive. • Method 2- via a serial port direct from DNA series You must have the instrument connected to the computer via the RS232 serial port. When using the Field Transfer/Input/Data Recorder or the Field Transfer/Output/Data Recorder commands with a DNA series device selected, ensure that the selection for the Comms Settings are the same on the instrument and the computer.

Software, operation via the keyboard, interface commands, protocols and data formats are covered in chapters 5 through 8. Chapter 9 covers error messages.

If there is not enough room in the selected file, an error message is displayed and no data is transferred. Resident evil 2 iso psx espaг±ol mega

Detail Title: Wild GIF10 REC-module reader Publisher: Wild Heerbrugg Classification: User manual Category: G2 354 en Instrument Class: valid for the following Wild instruments: T1000 (6 key, 14 key), TC1000, T1600, TC1600 T1010, TC1010, T1610, TC1610 T2000, TC2000, T2000S T2002, TC2002, T3000 NA2000, NA3000, NA2002, NA3003 Date: X.94 Pages: 56 Language: English The GIF10 is a data transfer unit, which permits data recorded in a REC-module to be transferred to a computer. The GIF10 and the computer communicate over a serial (RS232) interface. Several communication protocols are available and may be defined via the keyboard. The users manual describes the GIF10 hardware, power supply and interface in chapters 2 through 4. Software, operation via the keyboard, interface commands, protocols and data formats are covered in chapters 5 through 8.

History & comments circa 1990. Conservation No case. Condition in mint condition.

(This functionality is available with the Input / Output module) LISCAD supports the following measurement blocks: Word Index Function 11 Point ID 83 Bench Mark Height 331 Back Sight Reading 332 Foresight Reading 333 Intermediate Reading 52 Number of Observations The only recording method supported is BF (Backsight - Foresight) with Word Index 83 included in the measurement mask for all foresights and intermediate sights. NA Series Instruments (NA 2002 and NA 3003) This range of instruments use the GRM10 (Rec Module) to store the data.

A dialog box should be displayed asking if the data recorder is ready to receive data. If the GIF12 is connected to the appropriate parallel port of the computer and the GRM10 is in the GIF 12, press the OK button. A further dialog box is displayed asking you to 'Select the file to upload to on the GIF12'.

Transfer of data between a Digital Level and the system is via the Wild REC Module & GIF10 or Wild REC Module & GIF12 interface. DNA Series Instruments (DNA 03 and DNA 10) This range of instruments uses PCMCIA cards to store the data. There are two methods of transferring data between the DNA series and the system. • Method 1- via a PCMCIA drive You must have a PCMCIA drive installed in or connected to your computer, and the appropriate device drivers already loaded. Refer to your PCMCIA drive manual for details of these drivers. When using the Field Transfer/Input/Data Recorder or the Field Transfer/Output/Data Recorder commands with a DNA series device selected, ensure that the selection for the Comms Settings Port is correct for your PCMCIA drive.

All service and repair to T2000/2002/3000 are also offered.

City life edition 2008 serial code. • You can only upload files of type PNG, JPG, or JPEG.

(This functionality is available with the Input / Output module) Note that it may be necessary to have a battery installed in the GIF 12. Ensure that no other application is running that could use the parallel port (e.g. Print Manager). Transferring data from the GIF12 Ensure that you have carried out the appropriate steps in the procedure for up to the step for initiating the transfer of the data. You should then have a dialog box on the screen prompting you to 'Select the file to be downloaded' The files available in the GRM10 (REC Module) are displayed in the combo box below the above message. Select the required file and press the OK button to initiate the transfer. Transferring co-ordinate data to the GIF12 Use the command to put the system in a ready state to send co-ordinates to the GIF12.

Rec Group

Select the required file and press the OK button to initiate the transfer. Note that if the 'Overwrite existing data' check box is crossed, the data in the file selected will be overwritten by the transferred data. Otherwise the transferred data will be appended to the end of the file. If there is not enough room in the selected file, an error message is displayed and no data is transferred.

Rec Solar Panels Reviews

A dialog box should be displayed asking if the data recorder is ready to receive data. If the GIF12 is connected to the appropriate parallel port of the computer and the GRM10 is in the GIF 12, press the OK button. A further dialog box is displayed asking you to 'Select the file to upload to on the GIF12'. The files available in the GRM10 (REC Module) are displayed in the combo box below the above message. Select the required file and press the OK button to initiate the transfer. Note that if the 'Overwrite existing data' check box is crossed, the data in the file selected will be overwritten by the transferred data.